Appendix B: Performance Verification

B-42

AWG610 Arbitrary Waveform Generator User Manual

H Verify that the CH1 OUTPUT is off.

If the CH1 LED is on, push CH1 OUTPUT (front-panel) to turn the
LED off.

7. Set the trigger level to 5 V by following the substeps below:

a. Set the trigger level.

H Push SETUP (front-panel)!Trigger (bottom)!Level (side).

H Push 5 and ENTER keys in this order.

b. Set the offset level of generator.

H Push generator output ON.

H Push Cursor, %, &, , keys as the high level of a pulse to be set

to 4.65V.

c.

Verify that no waveform is displayed on the oscilloscope.

Trigger Signal CH2

(4.65 V level)

NOTE: In step 4b this

voltage level equals

4.65 V. In step 4d this

voltage level equals

5.35 V.

Figure B-16: Trigger Signal (+5V check1)

d. Push Cursor,

%, &, ,

keys as the high level of a pulse to be set to

5.35V.

e.

Verify that a sine wave is displayed on the oscilloscope.