QTECH QSW-2800 Инструкция по настройке User Manual

Page 106

Advertising
background image

+7(495) 797-3311 www.qtech.ru
Москва, Новозаводская ул., 18, стр. 1

92

Voltage high

RX power low

TX power low

Detail diagnostic and threshold information:

Diagnostic

Threshold

Realtime Value

High Alarm Low Alarm High Warn

Low Warn

--------------

-----------

-----------

----------

---------

Temperature (°C) 33

70

0

70

0

Voltage (V)

7.31(A+)

5.00

0.00

5.00

0.00

Bias current (mA) 6.11(W+)

10.30

0.00

5.00

0.00

RX Power (dBM)

-30.54(A-) 9.00

-25.00

9.00

-25.00

TX Power (dBM) -13.01(A-) 9.00

-12.00(-25.00) 9.00

-10.00(-25.00)

Example3:

Ethernet 1/21 is inserted the fiber module with DDM. Enable the transceiver monitoring of the

port after showing the transceiver monitoring of the fiber module.

Step1: Show the transceiver monitoring of the fiber module. Both ethernet 1/21 and ethernet

1/22 do not enable the transceiver monitoring, its interval is set to 30 minutes.

Switch(config)#show transceiver threshold-violation interface ethernet 1/21-22

Ethernet 1/21 transceiver threshold-violation information:

Transceiver monitor is disabled. Monitor interval is set to 30 minutes.

The last threshold-

violation doesn’t exist.

Ethernet 1/22 transceiver threshold-violation information:

Transceiver monitor is disabled. Monitor interval is set to 30 minutes.

The last threshold-

violation doesn’t exist.

Step2: Enable the transceiver monitoring of ethernet 1/21.

Switch(config)#interface ethernet 1/21

Switch(config-if-ethernet1/21)#transceiver-monitoring enable

Step3: Show the transceiver monitoring of the fiber module. In the following configuration,

ethernet 1/21 enabled the transceiver monitoring, the last threshold-violation time is Jan 02

11:00:50 2011, the detailed DDM information exceeding the threshold is also shown.

Switch(config-if-ethernet1/21)#quit

Switch(config)#show transceiver threshold-violation interface ethernet 1/21-22

Ethernet 1/21 transceiver threshold-violation information:

Transceiver monitor is enabled. Monitor interval is set to 30 minutes.

The current time is Jan 02 12:30:50 2011.

The last threshold-violation time is Jan 02 11:00:50 2011.

Advertising