Switch1#config

Switch1(config)#savi enable

Switch1(config)#savi ipv6 dhcp-slaac enable

Switch1(config)#savi check binding probe mode

Switch1(config)#interface ethernet1/1

Switch1(config-if-ethernet1/1)#ipv6 dhcp snooping trust

Switch1(config-if-ethernet1/1)#ipv6 nd snooping trust

Switch1(config-if-ethernet1/1)#exit

Switch1(config)#interface ethernet1/12-20

Switch1(config-if-port-range)#savi ipv6 check source ip-address mac-address

Switch1(config-if-port-range)#savi ipv6 binding num 4

Switch1(config-if-port-range)#exit

Switch1(config)#exit

Switch1#write

50.4 SAVI Troubleshooting

After ensure no problem about SAVI client hardware and cable, please check the status which

may exist and the propositional solutions in the following:

If IPv6 packets are filtered incorrectly after enable SAVI function, please ensure the global

SAVI function enabled. After that, enable the global function of the corresponding SAVI scene

according to the actual application scene and enable the port authentication function.

If client can not correctly obtain IPv6 address assigned by DHCPv6 server after enable SAVI

function, please ensure DHCP port trust is configured by uplink port with DHCPv6 server.

If node binding can not be set for the new user after enable SAVI function, please check

whether the direct-link port configures the max binding number, and whether the binding

number reaches to the max number. If the binding number exceeds the max binding limit, it is

recommended to configure the bigger binding limit.

If node binding can not be set for new user after configure the bigger binding limit, please

check whether the direct-link port configures the corresponding binding number, and whether

the corresponding binding number reaches to the max number in the same MAC address. If

the binding number exceeds the max binding limit, it is recommended to configure the bigger

binding limit.