A series – GE Industrial Solutions A Series Lighting Control Panelboards Modbus Register Map User Manual

Page 5

Advertising
background image

A Series

®

Lighting Controller Modbus Register Map

List of Tables

i

Table 1. Function codes supported by the Lighting Controller.......................................................................................3

Table 2. Exception response codes. ..................................................................................................................................3

Table 3. Object types supported by the Lighting Controller............................................................................................4

Table 5. Types of fixed-value registers. .............................................................................................................................5

Table 6. Sample packet for device product ID..................................................................................................................6

Table 7. Sample packet for device latitude and longitude...............................................................................................6

Table 8. Sample packet for device last reset date, time, and count. ................................................................................6

Table 9. Types of fixed-value registers. .............................................................................................................................7

Table 10. List of physical input registers...........................................................................................................................8

Figure 1. Sample display of 16 switch inputs.....................................................................................................................9

Table 11. Sample packet for read of MI Reg1 to Reg16. ..................................................................................................9

Table 12. Sample packet for read of MI Reg1 to Reg3. ....................................................................................................9

Table 13. Sample packet for read of MI Reg15 to Reg18. ..............................................................................................10

Table 14. Sample packet for write of MI Reg15. .............................................................................................................10

Table 15. Multi-state Input Configuration 1 ...................................................................................................................11

Table 16. Multi-state Input Configuration 2 ...................................................................................................................11

Table 17. MIC associated with each Multi-state Input ...................................................................................................11

Table 18. Format of Multi-state Input associated MIC reference...................................................................................12

Table 19. Analog Input Registers ....................................................................................................................................13

Table 20. Analog Input Property Registers .....................................................................................................................13

Table 21. Property of AI1 object ......................................................................................................................................14

Table 22 Sample packet for read of AI1 register.............................................................................................................14

Table 23.Sample packet for read of AI 601 register........................................................................................................15

Table 24 Analog Variable Registers.................................................................................................................................16

Table 25. Analog Variable Properties..............................................................................................................................16

Table 26. List of physical output registers (coils)...........................................................................................................17

Table 27. Sample packet for coil status of BO Reg2 to Reg17........................................................................................17

Table 28. Sample packet for coil status of BO Reg2 to Reg19........................................................................................18

Table 29. Sample packet for coil status of BO Reg62 to Reg 66.....................................................................................18

Table 30. List of physical output registers (OutOfService)............................................................................................19

Table 31. Sample packet for multiple write to output Reg220–Reg229.........................................................................19

Table 32. Sample packet for write to output Reg201......................................................................................................19

Table 33. Binary Output (BO) Registers ........................................................................................................................20

Table 34. Address space of binary output registers.........................................................................................................20

Table 35. Sample packets for read of all BO1 properties. ..............................................................................................21

Table 36. Sample packets for single write to BO1 overwrite time. .................................................................................21

Table 37. Sample packets for multiple write to binary output. ......................................................................................21

Table 38. List of feedback registers. ................................................................................................................................22

Table 39. Sample packets for output feedback instances 1–19 ......................................................................................22

Table 40.Special output Registers ...................................................................................................................................23

Table 41. Request to read BO67-BO70............................................................................................................................23

Table 43. Lighting Group output registers. ....................................................................................................................26

Table 44. Sample packets for LG Value Reg302 to Reg305............................................................................................26

Table 45. Lighting Group OutOfService registers. .........................................................................................................26

Table 46. Sample packets for LG out of Service instance 401–416. ...............................................................................26

Table 47 different lighting group registers .....................................................................................................................27

Advertising