Installation

5

© Gardner Denver Deutschland GmbH

21

/

74

05.2014 · 610.00260.40.000

when mounting the adapter plates, ensure that all four screws, including the
spring elements are tightened by applying the correct torque! All contact
areas must be dirt/ paint-free, as correct protective earth connection can-
not be ensured otherwise.

6. Reattach the original terminal board (8) to the motor, possibly with the aid of

the terminal board expansion option (7) and the elongated screw option (9).

7. Connect four wires (PE, U, V, W) with the appropriate cross section (depend-

ing on the output of the drive controller used) to the original terminal board.

The connecting wires required for wiring the motor terminal board/ drive
controller are not include in the delivery in the case of spare parts.

8. Screw the support (6) onto the adapter plate using the four fastening screws

with spring elements (4). Please pay attention to the proper seating of the
gasket (5). Insert the four wires (PE, U, V, W) into the support of the drive con-
troller.

9. Plug the drive controller onto the support (6) and secure it evenly using the

two M8 screws
(torque: max. 21.0 Nm [15.5 ft lbs]).

Jumper

10. Wire any available connection cable of the Motor PTC/ Klixxon to terminals T1

and T2 (1) (torque: 0.6 Nm [0.44 ft lbs]).

when installing, make sure that the connection cables are not pinched.

If the motor is equipped with a temperature sensor, it is connected to ter-
minals T1 and T2 (1) and the jumper (2) included in the delivery must be re-
moved. If the jumper is used, there is no temperature monitoring of the mo-
tor!