7

Parameters

610.00260.40.000 · 05.2014

54

/

74

© Gardner Denver Deutschland GmbH

5.070

Motor current limit

Unit: %

Relationship to
parameter:
5.071
33.031

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 250

Def: 0

0 = disabled

5.071

Motor current limit

Unit: s

Relationship to
parameter:
5.070
33.031

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 100

Def: 1

5.075

Transmission factor

Unit:

Relationship to
parameter:
33.034

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 10000

Def: 1

Here, a transmission factor can be set.
With the help of the transmission factor, the display of the me-
chanical speed can be adapted.

Blocking detection

5.080

Blocking detection

Unit: Integer

Relationship to
parameter:
5.081

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 1

Def: 0

Using this parameter, the blocking detection can be enabled.
0 = inactive
1 = active

5.081

Blocking time

Unit: s

Relationship to
parameter:
5.080

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 50

Def: 2

Specifies the time after which a blocking is detected.

5.090

Change in the parameter set

Unit: Integer

Relationship to
parameter:

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 7

Def: 0

Selection of the active record.
0 = not assigned
1 = record 1, active
2 = record 2, active
3 = digital input 1
4 = digital input 2
5 = digital input 3
6 = digital input 4
7 = integrated soft - PLC
. The second record is displayed on the PC software only if this
parameter is <> 0. The values of the currently selected record
are shown on the display of the hand-held unit.

7.3.12