Parameters – Elmo Rietschle 2FC4...-1CB User Manual

Page 57

Advertising
background image

Parameters

7

© Gardner Denver Deutschland GmbH

57

/

74

05.2014 · 610.00260.40.000

I

2

T

33,010

I

2

T factor of the motor

Unit: %

Relationship to
parameter:
33.031
33.101

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 1000

Def: 0

Here, the percentage of current threshold (based on the motor
current 33,031) can be adjusted at the start of integration.

33,011

I

2

T time

Unit: s

Relationship to
parameter:
33,100

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 1200

Def: 25

Time after which the drive controller turns off with I

2

T.

33,138

Holding current time

Unit: s

Relationship to
parameter:
33,100

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 128000

Def: 2

Only for asynchronous motors.
Is the time interval during which the drive is maintained with
direct current after stoppage of the braking ramp.

Switching frequency

The internal switching frequency (clock frequency) can be varied to control the
power unit. A high setting value leads to noise reduction in the motor, but also to
increased EMC emission and higher losses in the drive controller.

34.030

Switching frequency

Unit: Hz

Relationship to
parameter:

Parameter HB:

S. xy

Transfer

status:

2

min: 1

Intrinsic value
(to be en-
tered!
)

max: 4

Def: 2

Selecting the switching frequency of the inverter.
1 = 16 kHz
2 = 8 kHz
4 = 4 kHz

Controller data

34.010

Control mode

Unit: Integer

Relationship to
parameter:
33.001
34.011

Parameter HB:

S. xy

Transfer

status:

2

min: 100

Intrinsic value
(to be en-
tered!
)

max: 201

Def: 100

Selection of the control mode.
100 = open -loop asynchronous motor
101 = close- loop asynchronous motor
200 = open-loop synchronous motor
201 = close- loop synchronous motor

7.4.2