Error detection and elimination – Elmo Rietschle 2FC4...-1CB User Manual

Page 63

Advertising
background image

Error detection and elimination

8

© Gardner Denver Deutschland GmbH

63

/

74

05.2014 · 610.00260.40.000

No. Error name

Error description

Possible cause / remedy

13

External error 1

The parametrised error input is
active. 5.010

Eliminate external error

14

External error 2

The parametrised error input is
active. 5.011

Eliminate external error

15

Motor recognition

Motor identification errors

Check the connections to the
drive controller / motor and PC /
MMI hand-held unit / the drive
controller! Restart of the motor
identification!

16

IGBT trip

Protection of the IGBT module
from overcurrent has been trig-
gered

Short circuit in motor or motor
cable / controller settings

17

Intermediate circuit over-voltage The maximum intermediate

circuit voltage has been ex-
ceeded

Recovery through motor in re-
generative operation / mains
voltage too high / incorrect set-
ting of the speed controller /
braking resistor is not con-
nected or defective / ramp times
too short

18

Intermediate circuit undervolt-
age

The minimum intermediate cir-
cuit voltage was not reached

Mains voltage too low / mains
defective / check wiring

19

Motor overtemperature

Motor PTC has been triggered

Overload of the motor (e.g. high
torque at low speed) / ambient
temperature too high

20

Interruption in mains supply

One phase missing / mains volt-
age supply is interrupted

21

IGBT module overtemperature

IGBT module overtemperature

Insufficient cooling, low speed
and high torque, clock fre-
quency too high

22

Overcurrent

Maximum output current of the
inverter exceeded

Cooling insufficient / low speed
and high torque / clock fre-
quency too high / ramp times
too small / brake not opened

23

Drive controller overtemperature Internal temperature too high

Cooling insufficient / low speed
and high torque / clock fre-
quency too high / continuous
overload / reduce ambient tem-
perature / check fan

24 I

2

T motor protection switch-off

The internal I

2

T motor protection

(parametrisable) has been trig-
gered

Continuous overload

25

Grounding

Grounding of a motor phase

Insulation fault

26

Motor connection interrupted

No motor current despite con-
trol by the drive controller

No motor connected

27 Motor

parameter Plausibility

check of the motor

parameters has failed

Parameter set not OK

28 Drive

controller

parameters

Plausibility check of the drive
controller parameters has failed

Parameter set not OK, motor
type 33,001 and control mode
34,010 not plausible

29

Type plate data

No motor data has been en-
tered.

Enter motor data according to
the rating plate

30

Limitation of power classes

Max. overload of the drive con-
troller exceeded for more than
60 seconds.

Check application / reduce load
/ scale-up the drive controller
size

Advertising
This manual is related to the following products: