Parameters – Elmo Rietschle 2FC4...-1CB User Manual

Page 38

Advertising
background image

7

Parameters

610.00260.40.000 · 05.2014

38

/

74

© Gardner Denver Deutschland GmbH

Standby function for PID process control

Fixed frequency:

In this operating mode, fixed frequency setpoints are passed on to the motor con-
trol. There are 7 fixed frequencies (2,051 - 2,057) which are linked in BCD format
to the digital inputs 1 to 3. These seven fixed frequencies can be enabled via the
parameter "Auswahl_Festfrequenz(Selection_fixed_frequency)" (2,050) into three
groups:

0 = fixed frequency 1, 1 = fixed frequency 1 to 3, 2 = fixed frequency 1 to 7.

Logic table of fixed frequencies

DI 3

DI 2

DI 1

Selection

Parameters Presetting

0 0

1

Fixed

fre-

quency 1

2,051 34

Hz

0 1

0

Fixed

fre-

quency 2

2,052 67

Hz

0 1

1

Fixed

fre-

quency 3

2,053 50

Hz

1 0

0

Fixed

fre-

quency 4

2,054 0

Hz

1 0

1

Fixed

fre-

quency 5

2,055 0

Hz

1 1

0

Fixed

fre-

quency 6

2,056 0

Hz

1 1

1

Fixed

fre-

quency 7

2,057 0

Hz

Advertising