Commissioning – Elmo Rietschle 2FC4...-1CB User Manual

Page 34

Advertising
background image

6

Commissioning

610.00260.40.000 · 05.2014

34

/

74

© Gardner Denver Deutschland GmbH

Commissioning steps

The drive control can be parameterised on the motor prior to installation.
 To this end, the drive controller has a 24-V low-voltage input, which powers

the electronic parts, and without which a mains voltage must be supplied.

Commissioning can be done with a USB PC communication cable to connector
M12 with integrated RS485/RS232 interface converter (2FC4521-0ER00) or via the
MMI hand-held unit, including connection cable RJ11 to connector M12
(2FX4520-0ER00).

Start up the integrated drive control

Prior to delivery, the motor data set was installed on the drive control and requires
no further settings.

With a high signal on terminal strip X5 through the hardware release (En-HW) on
terminal no. 10 and software release on terminal no. 6 (digital input 1), the drive
control can be put into operation (e.g. control via analogue input 1 with 0-10 V).

Commission the drive control wall assembly and replacement

Commissioning with PC

1. Install PC software (you can obtain program software free of charge from the

manufacturer or at www.gd-elmorietschle.de).
Required operating system Windows XP or Windows 7 (32/64 bit). It is rec-
ommended to carry out the installation as the administrator.

2. Connect the PC via connection cable to the M12 connector M1.

3. Load the motor data set and continue with the application settings.

OR
determine the motor data set (parameters 33,030 to 33,050). If necessary, op-
timise the speed controller (parameter 34.100 to 34.101).

Motor data rating plate (example)

6.4

6.4.1

6.4.2

Advertising
This manual is related to the following products: