Analogue output

4.100

AO1 function

Unit: Integer

Relationship to
parameter:
4.101
4.102

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 40

Def: 5

Selection of the process value that is output at the analogue
output.
Depending on the process value selected, the standard
(4,101/4,102) must be adapted.
0 = not assigned / DRIVE CONTROLLER soft PLC
1 = intermediate circuit voltage
2 = mains voltage
3 = motor voltage
4 = motor current
5 = actual frequency
6 = speed measured externally by speed sensor (if available)
7 = current angle or position (if available)
8 = IGBT temperature
9 = inner temperature
10 = analogue input 1
11 = analogue input 2
12 = rated frequency
13 = motor power
14 = torque
15 = field bus
16 = PID setpoint (above V3.60)
17 = PID feedback (above V3.60)

4.101

AO1 Norm. Low

Unit:

Relationship to
parameter:
4.100

Parameter HB:

S. xy

Transfer

status:

2

min: -10000

Intrinsic value
(to be en-
tered!
)

max: +10000

Def: 0

Describes the range to be resolved to the output voltage 0 - 10
V or output current 0 - 20mA.

4.102

AO1 Norm. High

Unit:

Relationship to
parameter:
4.100

Parameter HB:

S. xy

Transfer

status:

2

min: -10000

Intrinsic value
(to be en-
tered!
)

max: +10000

Def: Type-
specific

Describes the range to be resolved to the output voltage 0 - 10
V or output current 0 - 20mA.