Technical data

610.00260.40.000 · 05.2014

64

/

74

© Gardner Denver Deutschland GmbH

Technical data

General data

Technical data 400 V devices

Size

MA

MB

MC

MD

Recommended motor power

(4 -pin asynchronous motor)

1,5 2,2

3,0

4,0

5,5

7,5

11,

0

15,

0

18,

5

22,

0

Ambient temperature

-25°C [-13°F] (non-condensing) up to +50°C [+122°F] (without derating) *

Mains voltage[V]

3~ 400 -10% – 480 +10%

Mains frequency [Hz]

4 – 63

Line system configurations

TN/TT

Mains current [A]

3,3

4,6

6,2

7,9

10,8

14,8

23,

3

28,

3

33,

3

39,

9

Rated current, effective

[IN at 8 kHz / 400 V]

4,0 5,6

7,5

9,5

13,0

17,8

28,

0

34,

0

40,

0

48,

0

Minimum braking resistance

[Ω]

100

50

50

30

Maximum overload

150% of rated current for 60 s

13

0%

Switching frequency [kHz]

4, 8, 16 (factory setting 8)

Cyclic frequency [Hz]

0 – 400

Protection function

Over/undervoltage, I

2

t limitation, short circuit, motor inverter temperature,

anti-tilt protection, anti-lock system

Process control

Freely configurable PID controller

Dimensions

L x B x H [mm]

233 x 153 x 120

270 x 189 x 140

307x223x181

414 x 294 x 232

Weight including adapter

plate [kg]

3,9 5,0

8,7

21,0

Protection class [IPxy]

65

55

EMC

met according to DIN EN 61800-3, class C2

*according to UL standard 508C, see Approval according to UL [➙ 73].

Designation

Function

Digital inputs 1-4

- Switching level low < 5V / high > 15 V
- Imax (at 24 V) = 3mA
- Rin = 8.6 kOhm

Analogue inputs 1, 2

- Input +/- 10V or 0 - 20mA -
input 2 - 10V or 4 - 20mA
- resolution 10 bit
- Rin = 10kOhm

Digital outputs 1, 2

- Short-circuit-proof
- Imax = 20 mA

Relay 1, 2

1 changeover contact (NO/ NC)
maximum switching power*:
- for resistive load (cos j = 1): 5 A ~ 230 V or 30 V
- at inductive load (cos j = 0.4 and L/ R = 7 ms): 2 A ~ 230 V or = 30 V
maximum response time: 7 ms ± 0.5 ms
electric service life: 100,000 switching cycles

Analogue output 1 (current)

- Short-circuit-proof
- I output = 0 to 20 mA
output load = 500 Ohm