Parameters

7

© Gardner Denver Deutschland GmbH

49

/

74

05.2014 · 610.00260.40.000

4.033/4.063

AIx - physical unit

Unit:

Relationship to
parameter:
4.034/4.064
4.035/4.065

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 10

Def: 0

Selection of the different physical variables to be displayed.
0 = %
1 = bar
2 = mbar
3 = psi
4 = Pa
5 = m

3

/h

6 = l/min
7 = °C
8 = °F
9 = m
10 = mm

4.034/4.064

Alx physical minimum

Unit:

Relationship to
parameter:
4.033/4.063
4.035/4.065

Parameter HB:

S. xy

Transfer

status:

2

min: -10000

Intrinsic value
(to be en-
tered!
)

max: +10000

Def: 0

Selection of the lower limit of a physical quantity to be dis-
played.

4.035/4.065

AIx - physical maximum

Unit:

Relationship to
parameter:
4.033/4.063
4.035/4.065

Parameter HB:

S. xy

Transfer

status:

2

min: -10000

Intrinsic value
(to be en-
tered!
)

max: +10000

Def: 100

Selection of the upper limit of a physical quantity to be dis-
played.

Digital inputs

4.110 – 4.113

DIx inverse

Unit: Integer

Relationship to
parameter:

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 1

Def: 0

Using this parameter, the digital input can be inverted.
0 = inactive
1 = active

7.3.6