Derating due to installation altitude

The following applies to all drive controllers:

▪ In S1 mode, no power reduction is required up to 1,000 m above sea level.

▪ In the range from 1,000 m up to and including 2000 m, power reduction of 1%

is required for every 100 m installation altitude. An overvoltage category 3 is
observed!

▪ In the range from 2,000 m up to and including 4,000 m, the overvoltage cate-

gory 2 must be observed due to the lower air pressure!

To comply with the overvoltage category:

▪ an external surge protector should be used in the mains supply line to the

drive controller.

▪ the input voltage should be reduced.

Please contact the manufacturer.

The respective max. output values can be defined, based on the following charac-
teristic curves.

Derating of the maximum output current due to the installation altitude

Derating of the maximum input voltage due to the installation altitude