Parameters – Elmo Rietschle 2FC4...-1CB User Manual

Page 60

Advertising
background image

7

Parameters

610.00260.40.000 · 05.2014

60

/

74

© Gardner Denver Deutschland GmbH

34.226

Starting current

Unit: %

Relationship to
parameter:
34.227

Parameter HB:

S. xy

Transfer

status:

2

min: 5

Intrinsic value
(to be en-
tered!
)

max: 1000

Def: 25

Only for synchronous motors.
The flow which is set in the motor prior to its start can be ad-
justed here. Value in % of the rated motor current.

34.227

Initialisation time

Unit: s

Relationship to
parameter:
34.226

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 100

Def: 0,25

Only for synchronous motors.
The time in which the starting current is 34,226 is applied can be
set here.

34.228–

34.230

Start-up behaviour

Unit: Integer

Relationship to
parameter:

Parameter HB:

S. xy

Transfer

status:

2

min: 0

Intrinsic value
(to be en-
tered!
)

max: 1

Def: 0

Only for synchronous motors.
Larger starting torques can be achieved by changing the start-
up procedure to the "controlled" mode.
0 = regulated, the inverter switches directly to the control mode
after the setting phase.
1 = controlled, following the setting phase, the field of rotation is
increased to the starting frequency 34,230 controlled with the
start-up ramp 34,229, then it is switched to the regulation mode.