101

.

Table 17: Trunk/test switches

Switch
number

Circuit
number

1

1

2

1

3

2

4

2

5

3

6

3

7

4

8

4

9

5

10

5

11

Not Used

12

Test Switch

Table 18: Pin assignments for 25-pair connector

26

W-BL

TTC1

Tip-PBX Trunk Circuit 1

1

BL-W

RTC1

Ring-PBX Trunk Circuit 1

27

W-O

TTK1

Tip-CO Trunk Circuit 1

2

O-W

RTK1

Ring-CO Trunk Circuit 1

28

W-G

TLC1

Tip-PBX Line Port 1

3

G-W

RLC1

Ring-PBX Line Port 1

29

W-BR

TST1

Tip-Emergency Terminal 1

4

BR-W

RST1

Ring-Emergency Terminal 1

30

W-S

TTC2

Tip-PBX Trunk Circuit 2

5

S-W

RTC2

Ring-PBX Trunk Circuit 2

31

R-BL

TTK2

Tip-CO Trunk Circuit 2

6

BL-R

RTK2

Ring-CO Trunk Circuit 2

1 of 3