Connecting the cables – Avaya 03-300686 User Manual

Page 121

Advertising
background image

1152A1 Mid-Span Power Distribution Unit

Issue 3 January 2008

121

To connect the 1152A1 Power Distribution Unit:

1. Plug a power cord into the power socket on the rear of the 1152A1 Power Distribution Unit.

2. Plug the other end of the power cord into the power receptacle.

The 1152A1 PDU powers up, and the internal fans begin operating.

The 1152A1 PDU then runs through its Power On Self Test (POST), which takes less than
10 seconds. During the test, all the ports on the unit are disabled and the LEDs light up. For
more information on the test, see the user’s guide that comes with the unit.

Connecting the cables

All of the ports on the front of the 1152A1 PDU are configured as data route-through ports for all
data wires (pins 1, 2, 3 and 6).

Use a standard CAT5, CAT6 or CAT6e straight-through Ethernet cable (not supplied), including
all eight wires (4 pairs) as shown in

Figure 55: Connecting telephones and other end devices to

the 1152A1 PDU

on page 121.

Figure 55: Connecting telephones and other end devices to the 1152A1 PDU

For Data-In ports connect the Ethernet cable leading from the Ethernet Switch/Hub to the Data
port. For Data & Power Out ports, connect the Ethernet cable leading to the telephone or other
end device to the corresponding Data & Power port.

Note:

Note:

Be certain to connect correspondingly numbered Data and Data & Power ports.

AC

Console

1

2

3

4

5

6

13

14

15

16

17

18

19

20

21

22

23

24

7

8

9

10

11

12

1152A1 Power
Distribution Unit

Data &

Power

Data

48Vdc

End Device

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

RJ-45 IN

RJ-45 OUT

Ethernet

Switch/Hub

RJ

-4

5

RJ

-4

5

data

data

data

DC +
data

DC -

data

data

data

data

spare
spare

spare
spare

Da

ta

In

Da

ta

&

P

ow

e

r O

u

t

DC +

DC -

1152A1 Power Distribution Unit