Connecting trunk pairs to media gateway, Using jumper wires to establish 3-pair modularity – Avaya 03-300686 User Manual

Page 67

Advertising
background image

Installing and administering the patch cord/jumper

Issue 3 January 2008

67

Connecting trunk pairs to media gateway
using jumper wires to establish 3-pair modularity

Figure 32: 3-pair modularity for trunk pairs for 1-pair trunks

on page 67 and

Figure 33: 3-pair

modularity for trunk pairs for 3-pair Tie trunks

on page 68 show trunk pairs connected to the

media gateway with jumper wires to establish 3-pair modularity.

To connect the trunk pairs to the purple field:

1. Connect B25A cables between the network interface and the sneak fuse panels. See

Figure 32: 3-pair modularity for trunk pairs for 1-pair trunks

on page 67.

2. Connect A25D/B25A cables from the sneak fuse panels to the 110-type terminal block-type

connecting block connectors in the green field.

3. Connect 1-pair patch cords/jumper wires from each 110-type terminal block row in the green

field to the 110-type terminal block rows in the purple field for 1-pair central office (CO)
trunks or in

Figure 33: 3-pair modularity for trunk pairs for 3-pair Tie trunks

on page 68 for

3-pair tie trunks.

Figure 32: 3-pair modularity for trunk pairs for 1-pair trunks

Figure notes:

1. Green Field
2. 1-Pair Jumpers

3. Pairs
4. Purple Field

1