Testing the complete configuration

146 Installing and Connecting the MDF and Telephones

Testing terminating trunk transmission

The terminating trunk transmission test provides for extension number access to 3 tone
sequences that can be used for trunk transmission testing from the distant end of the trunks. To
test terminating trunk transmission:

1. Type change system-parameters maintenance and press Enter and go to screen 2.
2. Under TERMINATING TRUNK TRANSMISSION TEST (Extension), type in 3 extension

numbers in the 3 fields provided:

Test Type 100:_______Test Type 102:_______Test Type 105:_______

Test type

Test features

Test type

100

5.5 seconds of 1004 Hz tone at 0 dB
Quiet until disconnect; disconnect is forced after 1 minute

Test Type

102

9 seconds of 1004 Hz tone at 0 dB
1 second of silence
Cycle is repeated until disconnect, which is forced after

24 hours

Test Type

105

9 seconds of 1004 Hz tone at -16 dB
1 second of silence
9 seconds of 404 Hz tone at -16 dB
1 second of silence
9 seconds of 2804 Hz tone at -16 dB
30 seconds of silence
0.5 seconds of test progress tone (2225 Hz)
About 5 seconds of silence
Forced disconnect