Installing external ringing – Avaya 03-300686 User Manual

Page 106

Advertising
background image

Installing and wiring telephones and trunks

106 Installing and Connecting the MDF and Telephones

Installing external ringing

Connections for external ringing are at an information outlet. The media gateway side of the
MDF is connected to a TN2183 (or equivalent) Analog Line circuit pack. The circuitry and power
source for the device are provided by the customer.

Note:

Note:

A maximum of three devices can connect to one analog line circuit pack port.

To install external ringing:

1. Wire the ringing device to the information outlet as shown in

Figure 51: 3-pair and 4-pair

modularity

on page 106 and

Figure 41: Example adjunct power connections

on page 85.

2. Administer per the Administrator Guide for Avaya Communication Manager (03-300509).

Figure 51: 3-pair and 4-pair modularity

Figure notes:

1. Port Circuit Pack
2. Media Gateway Connector Pins

(3-Pair Modularity)

3. Main Distribution Frame (MDF)

Pins (3-Pair Modularity)

4. Input to Information Outlet

(4-Pair Modularity)

5. Adjunct Power
6. Output From Information Outlet

(4-Pair Modularity)

7. Voice or Data Terminal Pins

Advertising