Connecting adjunct power, Figure 34: 302d to 4-wire dcp wiring – Avaya 03-300686 User Manual

Page 74

Advertising
background image

Installing and wiring telephones and trunks

74 Installing and Connecting the MDF and Telephones

Figure 34: 302D to 4-wire DCP wiring

Connecting adjunct power

The 400B2 adapter is convenient for connecting local -48 VDC power to a modular plug. See

Figure 35: 400B2 Adapter connecting to a modular plug

on page 75.

Each port network can provide power for up to three attendant consoles. This source of power
is preferred for the attendant consoles because it has the same battery backup as the media
gateway. See

Auxiliary connector outputs (MCC1 and SCC1 Media Gateways only)

on page 81.

Note:

Note:

Adjunct power can be provided locally at the telephone or console by either the
1151B1 or 1151B2 power supply. Adjunct power can be provided from the
equipment room or equipment closet with the 1145B power unit. See

Installing

and wiring telephone power supplies

on page 109 for power supply information

and installation procedures.

Figure notes:

1. 302D Attendant Console
2. 4-wire Digital Line Circuit Pack

(Position 1C02)

3. -48 VDC From Adjunct Power
4. Ground From Adjunct Power

302cwire RBP 040596