Site locations, Station circuit distribution from equipment room – Avaya 03-300686 User Manual

Page 44

Advertising
background image

MDF connections to stations and the public switched telephone network

44 Installing and Connecting the MDF and Telephones

Satellite locations using 110-type hardware

Each terminal block has a 3-pair (white field) and a 4-pair (blue field) located on the same
terminal block.
The 110A-type terminal block that can be used is the 110AE1-75FT. It must be field-terminated
to both the white and blue fields.
The 300-pair 110P-type terminal blocks that can be used are:

110PE1-300CT/FT — 25-pair connector on the white field and field-terminated on the blue
field

110PE1-300FT — Field-terminated on both the white and blue fields

The 900-pair 110P-type terminal blocks that can be used are:

110PE1-900CT/FT — 25-pair connector on the white field and field-terminated on the blue
field

110PE1-900FT — Field-terminated on both the white and blue fields

Site locations

Site locations are closets that provide a point in the station wiring for the administration of
remote powering. Adapters are used at site locations to terminate the 25-pair station cables and
provide connection points (modular jacks) for power adapters and 4-pair station cables.
The 258A and BR2580A adapters plug into a 25-pair female cable connector. These adapters
divide the 25-pair cable into six 4-pair (modular jack) circuits. See

Figure 23: 258A and

BR2580A Adapters

on page 50.

The 356A adapter plugs into a 25-pair female cable connector. See

Figure 24: 356A

Adapter

on page 51. The 356A adapter divides the 25-pair cable into eight 3-pair circuits.

Although the circuits are 3-pair, the adapters modular jacks will accept the 8-wide modular plug
used on the 4-pair station cable.

!

CAUTION:

CAUTION:

Adapters wired similarly to the 356A should not be used. Their jacks do not
accept 4-pair plugs.

Station circuit distribution from equipment room

This section explains the station circuit distribution from the equipment room to the information
outlets for new wiring installations. Example connection diagrams are provided to show the
options for running and connecting the station cables.