Pair station circuits, Pair to 4-pair station circuit distribution – Avaya 03-300686 User Manual

Page 45

Advertising
background image

Station circuit distribution from equipment room

Issue 3 January 2008

45

If most of the telephones/voice terminals that require remote powering are within 250 feet (76.2
meters) of the equipment room, 4-pair station circuits are run from the equipment room to the
information outlets. If this is not the case, or if the customer requires 2-point administration,
3-pair station circuits are run from the equipment room to satellite locations. Then, the 4-pair
station circuits are run from the satellite locations to the information outlets.
This section has information about

4-pair station circuits

on page 45

3-pair to 4-pair station circuit distribution

on page 45

Connected cable station adapters

on page 50

Lists of telephones and consoles currently sold are provided in

Table 7: Connectable telephone

and consoles

on page 70.

4-pair station circuits

Four-pair circuits, via station cables, can be run directly from an equipment room MDF to a
258A or BR2580A adapter as shown in

Figure 18: 4-pair circuit distribution and connectivity

on

page 46. The 4-pair station cables connect the adapter to the information outlets.
The 4-pair station cables can be run directly from the equipment room to the information outlets
if 4-pair terminal blocks are used in the distribution field. See

Figure 19: 4-pair run to equipment

room or satellite location

on page 47. The station cables must be field-terminated on the

110-type terminal blocks.
If 110-type terminal blocks are used with a modular plug-ended station cable, an adapter can be
connected directly to the 110-type terminal block connectors. See

Figure 20: 4-pair run to

equipment room or satellite location

on page 47.

3-pair to 4-pair station circuit distribution

Figure 21: 3-pair to 4-pair satellite location connectivity

on page 48 shows the 3-pair circuit

distribution from an equipment room MDF to a satellite location using 110-type hardware.
Four-pair circuits are distributed from the satellite location to the information outlets.
Three-pair circuits can also be run directly from the equipment room MDF to a 356A adapter as
shown in

Figure 22: 3-pair to 4-pair circuit distribution and connectivity

on page 49. Four-pair

station cables connect the adapter to the information outlets. Four-pair station cables can be run
directly from a satellite location to the information outlets as previously described.

Note:

Note:

Bridged taps are not allowed on any part of the station wiring.

Advertising