Page 34

Advertising
background image

Media gateway connections to the MDF

34 Installing and Connecting the MDF and Telephones

Figure 12: Equipment room cabling labels

The top blue/yellow building and floor labels are for cables connecting from the equipment room
to a site/satellite location on another floor or in another building. The yellow label is for auxiliary
circuits connecting to the trunk/auxiliary field. The bottom blue/yellow label is for 25-pair cables
connecting to site/satellite closets. See

Table 2: Equipment room labels

.

Figure notes:

1. Purple Label (Port Cable)
2. Blue/Yellow Label (Building

and Floor)

3. Yellow Label (Auxiliary)
4. Blue/Yellow Label (Site or

Satellite)

Table 2: Equipment room labels

Label name

Range

Port Cable

1A1-1A20, 1B1-1B20,

1C1-1C20, 1D1-1D20,

1E1-1E20

Building

Field Identified

Floor

Field Identified

Auxiliary Cable

Field Identified

Site or Satellite

A-F and/or Field Identified

labels LJK 060396