Adjunct power connection locations

Figure 41: Example adjunct power connections

on page 85 shows typical connection locations

for adjunct power. Adjunct power for station equipment may be supplied from the equipment
room, satellite location, or the work location.

For this figure, the following example is used:

1. If 25 telephones are connected to the media gateway and all 25 telephones need adjunct

power, install a bulk power supply in the equipment room.

2. If only ten of the telephones need adjunct power, install a bulk power supply at the satellite

location.

3. If only one telephone needs adjunct power, install the individual power supply at the work

location.

Figure 41: Example adjunct power connections

Figure notes:

1. Typical Display Telephone
2. Individual Power Supply (Such as

1151B1 or 1151B2)

3. Information Outlet (Modular Jack)
4. 4-Pair D-Inside Wire (DIW) Cable
5. Satellite Site or Adapter Location
6. 25-Pair D-Inside Wire (DIW) Cable
7. Station Side of Main Distribution

Frame (MDF)

8. 100P6A Patch Cord or Jumpers
9. Media Gateway Side of Main

Distribution Frame (MDF)

10. 25-Pair Cable to Media Gateway

(Analog Line Circuit Pack)

11. Equipment Room

12. Satellite Location
13. Work Location
14. Bulk Power Supply (such as 1145B)