Installing and wiring telephones and trunks

90 Installing and Connecting the MDF and Telephones

4. Connect emergency transfer power (Blue-White and White-Blue)) as shown in

Table 14: Alarm Inputs at TN2312BP Adapter DB9 Alarm Connector

.

Installing off-premises station wiring

The local telephone company provides cabling outside the building for off-premises stations.
The off-premises stations can appear on any of the RJ21X network interfaces provided for the
central office (CO) trunks.

!

CAUTION:

CAUTION:

Only an FCC-approved (or equivalent) analog type telephone (such as a
2500-type), can be used as an off-premises station. The TN746B and TN2183
Analog Line circuit packs can be connected to off-premises stations.

To install the off-premises station wiring:

1. Install an A25D (male to male) cable between the RJ21X network interface and a sneak

fuse panel.

2. At the main distribution frame (MDF), connect jumper wires between one row/connecting

block in the green field and up to three rows/connecting blocks in the purple field to
concentrate the analog line pairs.

Table 14: Alarm Inputs at TN2312BP Adapter DB9 Alarm Connector

Color

AUX Connector

Pair Name

*

*. For additional information on the auxiliary field on the Main Distribution Field, see

Figure 49: Connections for telephone used for emergency transfer

on page 103 and

Figure 50: Connections for telephone used for emergency transfer and as normal
extension

on page 104.

White-Blue

Ground (Pin 2)

XR

Blue-White

XFER48 (Emergency Transfer) (Pin 1)

White-Orange

Ground (Pin 8)

1m

Orange-White

AP2 Minor Alarm Input (Pin 3)

White-Green

EXTALMB (Ground) Alarm Output (Pin 5)

AL

Green-White

EXTALMA Alarm Output (Pin 4)

White-Brown

Ground (Pin 7)

1M

Brown-White

AP1 Major Alarm Input (Pin 6)