Labeling expansion control carrier cable, Mcc1 media gateway only) – Avaya 03-300686 User Manual

Page 64

Advertising
background image

MDF connections to stations and the public switched telephone network

64 Installing and Connecting the MDF and Telephones

Figure 30: Example 4-pair labeling to information outlet

Labeling expansion control carrier cable
(MCC1 Media Gateway only)

To label the expansion control carrier cable:

1. Place the appropriate AUX connector label on the assigned 110-type terminal block row.

2. On the expansion control carrier cable, place a yellow auxiliary label on the connectors at

each end of the cable.

3. Write “AUX” on each label.

Figure notes:

1. Equipment Room
2. To Central Location for Terminals 1

through 6

3. Blue Row on 110 Terminal Block
4. Purple Row on 110 Terminal Block
5. To Port Connector on Media Gateway

(Media Gateway 1, Position B, Slot 03)

6. 258A Adapter
7. D-Inside Wire Cut Down to

Connecting Block

8. Information Outlet
9. Telephone

crdf4pr CJL 102996

Advertising