Installing the 808a emergency transfer panel, T. see, Figure 48: 808a emergency transfer panel mounting – Avaya 03-300686 User Manual

Page 99

Advertising
background image

808A Emergency Transfer Panel and telephone installation examples

Issue 3 January 2008

99

Figure 48: 808A Emergency Transfer Panel mounting

Installing the 808A Emergency Transfer Panel

Note:

Note:

The 808A must be installed in a location that can be accessed only by authorized
personnel. The location must meet standard environmental considerations such
as temperature, humidity, and so forth.

To install the 808A Emergency Transfer Panel:

1. Verify dial tone is present at each trunk circuit.

2. Locate the circuit start selection switches (see

Figure 47: 808A Emergency Transfer

Panel

on page 98).

These are the first 10 two-position switches on the left side of the Emergency Transfer
Panel. They are used to set each of the five incoming trunk lines to either loop start or
ground start. Two switches are used for each circuit; switches 1 and 2 are used for circuit 1,
switches 3 and 4 are used for circuit 2, and so forth. See

Table 17: Trunk/test switches

on

page 101.

3. For loop start, set the switches to the left. For ground start, set the switches to the right.

Figure notes:

1. 808A Emergency Transfer Panel
2. Ear for Screw Mount
3. Cut-Out for Snap Mount

4. 25-Pair Male Connector
5. Circuit Start Switches

808a_em LJK 042396