:BOOT[:WARM]

DIAGnostic:BOOT[ :WARM] causes the System Instrument to restart (re-boot)
using the current configuration stored in non-volatile memory. The effect is the
same as cycling power.

Comments

The System Instrument goes through its power-up self tests.

The non-volatile system state is used for configuration wherever
applicable.

Related Commands: DIAG:BOOT:COLD

Example

Booting the System Instrument (warm)

DIAG:BOOT:WARM

force boot

:COMMunicate

:SERial[0][:OWNer]

DIAGnostic:COMMunicate:SERial[ 0] [ :OWNer] < owner > Allocates the
built-in serial interface to the System Instrument, the optional IBASIC
interpreter, or to neither.

Parameters

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

owner

discrete

SYSTem| IBASic| NONE

none

Comments

While the serial interface is allocated to the Command Module
(SYSTem), it can function as the mainframe user interface when
connected to a terminal or computer running terminal emulation
software.

When the built-in serial interface is allocated to IBASIC, it is controlled
only by IBASIC. The serial interface is given a select code of 9, and any
RS-232 device connected to the (Command Module) RS-232 port is
programmed accordingly.

If the built-in serial interface is not needed, specifying NONE will release
memory for use by other instruments.

Once the new serial interface owner has been specified
(DIAG:COMM:SER:OWN), the change will not take effect until you
re-boot (warm) the system.

Related Commands: DIAGnostic:COMMunicate:SERial[:OWNer]

Example

Give the serial interface to IBASIC.

DIAG:COMM:SER IBAS

Note; :OWNer is implied

DIAG:BOOT:WARM

Complete the allocation

DIAGnostic :BOOT[:WARM]