Agilent Technologies E1300B User Manual

Page 165

Advertising
background image

Serial communication settings for the Agilent E1324A Datacomm
interface can be stored in its on-board non-volatile EEROM only after
the DIAG:COMM:SER[n]:STORe command is executed. These settings
are used at power-up and DIAG:BOOT[:WARM].

DIAG:BOOT:COLD will set the serial communication parameters to the
following defaults:

BAUD 9600
BITS 8
PARity NONE
SBITs 1
DTR ON
RTS ON
PACE XON

Example

Setting baud rate for plug-in card 2.

SYST:COMM:SER2:BAUD 9600

(must be a card number 1 also)

:COMMunicate

:SERial[n] :CONTrol

:DTR

SYSTem:COMMunicate:SERial[ n] :CONTrol:DTR < dtr_cntrl> controls the
behavior of the Data Terminal Ready output line. DTR can be set to a static
state (ON | OFF), can operate as a modem control line (STANDard), or can be
used as a hardware handshake line (IBFull).

Parameters

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

dtr_cntrl

discrete

ON| OFF| STANDard| IBFull

none

Comments

The following table defines each value of dtr_cntrl:

Value

Definition

ON

DTR line is asserted

OFF

DTR Line is unasserted

STANdard

DTR will be asserted when the serial interface is
ready to send output data. Data will be sent if the
connected device asserts DSR and CTS.

IBFull

While the input buffer is not yet at the :STOP
threshold, DTR is asserted. When the input buffer
reaches the :STOP threshold, DTR will be
unasserted.

DIAG:BOOT:COLD will set

DTR to ON.

Related Commands: SYST:COMM:SER[n]:CONT:RTS,
SYST:COMM:SER[n]:PACE:THR:STARt,
SYST:COMM:SER[n]:PACE:THR:STOP

*RST Condition: No change

Example

Asserting the DTR line.

SYST:COMM:SER0:CONT:DTR ON

SYSTem :COMMunicate :SERial[n] :CONTrol :DTR

System Instrument Command Reference 7-37