Command quick reference – Agilent Technologies E1300B User Manual

Page 203

Advertising
background image

1

Command Quick
Reference

The following tables summarize SCPI and IEEE 488.2 Common (*) commands
for the Agilent E1300/E1031 Mainframe System Instrument.

SCPI Commands Quick Reference

Command

Description

ABO Rt

[IMMediate]

Abort Pacer output.

D IAG nostic

:BO O T

:CO LD

Restarts System processor, clears stored configurations.

[:WARM]

Same as cycling power.

:CO MMunicate

:SERial[0]

[:O WNer] [SYSTem| IBASic| NO NE]

Allocates the built-in serial interface.

[:O WNer]?

Returns SYST, IBAS, or NO NE.

:SERial[n]

:STO Re

Stores serial communication parameters into non-volatile storage.

:D O WNload

:CH ECked

[:MAD D ress]

Write data to non-volatile user RAM starting at the specified address

using error correction.

:SAD D ress

Write data to non-volatile user RAM at the specified address using

error correction.

[:MAD D ress] < address> , < data>

Write data to non-volatile user RAM starting at the specified address.

:SAD D ress < address> , < data>

Write data to non-volatile user RAM at the specified address.

:D RAM

:AVAilable?

Returns the amount of RAM remaining in the D RAM (D river RAM)

segment.

:CREate < size> ,< num_drivers>

Creates a non-volatile RAM area for loading instrument drivers.

:D RIVer

:LO AD < driver_block>

Loads the instrument driver contained in the specified driver_block

into a previously created D RAM segment.

:LO AD

:CH ECked

Loads the instrument driver contained in the specified driver_block

into a previously created D RAM segment using error correction.

:LIST

[:ALL]

Lists all drivers from all driver tables (RAM and RO M)

:RAM

Lists all drivers found in the RAM driver table.

:RO M

Lists all drivers found in the RO M driver table.

:INTerrupt

:ACTivate [O N| O FF| 1| 0]

Enable VXIbus interrupt acknowledgement.

:SETup[n] [O N| O FF| 0| 1]

Enables or disables System Instrument control of VXI

interrupt line [n].

:SETup[n]?

Returns current state of SETup[n].

:PRIority[n] [<

priority> | MIN| MAX| DEF]

Specifies the priority level of VXI interrupt line [n].

:PRIority[n]? [MIN| MAX| D EF]

Returns priority level of VXI interrupt line [n].

:RESPonse?

Returns response from the highest priority interrupt line.

System Instrument

Command Quick Reference 7–75

Advertising
This manual is related to the following products: