:COMMunicate

:SERial[n] [:RECeive]

:PACE :THReshold

:STOP

SYSTem:COMMunicate:SERial[ n] [ :RECeive] :PACE:THReshold:STOP
< char_count
> configures the input buffer level at which the specified interface
may send the XOFF character (ASCII 13

16

), de-assert the DTR line, and/or

de-assert the RTS line.

Parameters

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

char_count

numeric

1 through 99 for built-in

1 through 8191 for E1324A

none

Comments

To determine the size of the input buffer of the serial interface you are
using, send SYST:COMM:SER[n]:PACE:THR:STOP? MAX. The
returned value will be the buffer size.

• …

STOP must be set to greater than

STARt.

The

THR:STOP command has no effect unless

PACE:PROT XON,

CONT:DTR IBF, or

CONT:DTR IBF has

been sent.

Related Commands:

PACE:PROT XON | NONE,

CONT:DTR,

CONT:RTS

*RST Condition: No change

Example

Set interface to send XOFF when input buffer contains 80 characters.

SYST:COMM:SER0:PACE:THR:STOP 80

:COMMunicate

:SERial[n] [:RECeive]

:PACE :THReshold

:STOP?

SYSTem:COMMunicate:SERial[ n] [ :RECeive] :PACE:THReshold:STOP?
[ MIN | MAX]
returns:

The current stop threshold if no parameter is sent.

The maximum allowable setting if MAX is sent.

The minimum allowable setting if MIN is sent.

Comments

To determine the size of the input buffer of the serial interface you are
using, send SYST:COMM:SER[n]:PACE:THR:STOP? MAX. The
returned value will be the buffer size.

Example

Return current stop threshold

SYST:COMM:SER0:PACE:THR:STOP?

query for threshold

enter statement

statement enters a numeric
value

SYSTem :COMMunicate :SERial[n] [:RECeive] :PACE :THReshold :STOP

System Instrument Command Reference 7-43