[:IMMediate]

TRIGger:IMMediate will cause a trigger cycle to occur immediately, provided
that the trigger system has been initiated (INITiate).

Comments

Related Commands: ABORt, INITiate

*RST Condition: This command is an event and has no *RST condition.

Example

Triggering the Pacer.

TRIG:SOUR HOLD

trigger source is TRIG
command

SOUR:PULS:COUN 1E3

output 1000 Pacer pulses

SOUR:PULS:PER .1 S

pulse period set to .1 second

TRIG:DELAY .75 S

start Pacer .75 sec after trigger

INIT

go to Wait For Trigger state

TRIG

trigger Pacer to output pulses.

:SLOPe

TRIGger:SLOPe < slope> is for SCPI compatibility. The mainframe’s "Event
In" signal only triggers on a negative going edge.

Parameters

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

slope

discrete

NEGative

none

Comments

Trying to set

SLOPe to other than NEG will generate an error.

Related Commands: ABORt, INITiate,

:SLOPe?

TRIGger:SLOPe? returns the current trigger slope setting. Since the
mainframe’s "Event In" signal only triggers on a negative going edge,
TRIG:SLOP? will always return "NEG".

:SOURce

TRIGger:SOURce < trig_source> configures the trigger system to respond to
the specified source.

Parameters

Parameter

Name

Parameter

Type

Range of

Values

Default

Units

trig_source

character

BUS| EXT| HOLD| IMM

none

TRIGger[:IMMediate]

7-52 System Instrument Command Reference