Fabric OS Encryption Administrator’s Guide (KMIP)

131

53-1002747-02

Viewing and editing encryption group properties

2

Connection Status: The switch’s connection status. Possible values are:

-

Group Leader: The switch designated as the Group Leader, so there is no connection
status.

-

Trying to Contact: The member is not responding to the Group Leader. This might occur if
the member switch is not reachable by way of the management port, or if the member
switch does not believe it is part of the encryption group.

-

Configuring: The member switch has responded and the Group Leader is exchanging
information. This is a transient condition that exists for a short time after a switch is added
or restored to a group.

-

OK: The member switch is responding to the Group Leader switch.

-

Not Available: The Group Leader is not a managed switch, so connection statuses are not
being collected from the Group Leader.

The Members table might not match the list of members displayed in the Encryption Center dialog
box if some configured members are unmanaged, missing, or in a different group.

NOTE

When the encryption group is in the Degraded state, the Members tab indicates the group member
that the leader cannot contact. If the non-responding switch should no longer be included in the
encryption group, it can be removed using the Remove button.

The Members tab (

Figure 107

) is viewed from the Encryption Group Properties dialog box. To

access the Members tab, select a group from the Encryption Center Devices table, then select
Group > Properties from the menu task bar.

NOTE

You can also select a group from the Encryption Center Devices table, then click the Properties icon.

FIGURE 107

Encryption Group Properties dialog box - Members tab

Advertising