High availability (HA) clusters

2

3. Click the right arrow to add the encryption engine to the selected HA cluster.

4. Click OK.

Removing engines from an HA cluster

Removing the last engine from an HA cluster also removes the HA cluster.

If only one engine is removed from the cluster, you must either add another engine to the cluster, or
remove the other engine.

1. Select Configure > Encryption from the menu task bar to display the Encryption Center

dialog box (Refer to

Figure 6

on page 14).

2. Select an encryption group from the Encryption Center Devices table, then select Group >

HA Cluster from the menu task bar.

The Encryption Group Properties dialog box displays, with the HA Clusters tab selected.

3. Select an engine from the High Availability Clusters table, then click the left arrow (Refer to

Figure 61

).

4. Either remove the second engine or add a replacement second engine, making sure all HA

clusters have exactly two engines.

5. Click OK.

Swapping engines in an HA cluster

Swapping engines is useful when replacing hardware. Swapping engines is different from removing
an engine and adding another because when you swap engines, the configured targets on the
former HA cluster member are moved to the new HA cluster member.

1. Select Configure > Encryption from the menu task bar to display the Encryption Center

dialog box.

2. Select an encryption group from the Encryption Center Devices table, then select Group >

HA Cluster from the menu task bar

The Encryption Group Properties dialog box displays, with the HA Clusters tab selected (Refer
to

Figure 61

).

To swap engines, select one engine from the High Availability Clusters table and one unclustered
engine from encryption engine from the Non HA Encryption Engines table, then click the
double-arrow.

NOTE

The two engines being swapped must be in the same fabric.