Figure 47 change jnl option pane, 47 change jnl option pane – HP StorageWorks XP Remote Web Console Software User Manual

Page 100

Advertising
background image

100 Continuous Access XP Journal

NOTE:

If an error occurs, the right-most column of the Preset list displays the error code. To view detailed

information about the error, right-click the error code, and select Error Detail. An error message appears

providing detailed information about the error.

Figure 47

Change JNL Option pane

The Change JNL Option pane displays the following:

Meta/Data Ratio: Specify the ratio of metadata area to journal data area. For example, if you select

16, the ratio of metadata area to journal data area is 1:16. If you select 32, the ratio of metadata area

to journal data area is 1:32.

NOTE:

Currently, you cannot change the ratio of metadata area to journal data area.

Extent: Specify the number of extents.

NOTE:

Currently, the number of extents is always 32 and cannot be changed.

Inflow Control: Specify whether inflow of update I/Os to the journal volume is restricted (in other

words, whether to slow delay response to hosts).
• Yes: Inflow is restricted.
• No: Inflow is not restricted.

NOTE:

If you select Yes and the metadata or journal data is full, update I/Os might stop.

Data Overflow Watch (0 to 600 sec): Time (in seconds) for monitoring whether metadata and journal

data are full. This value must be within the range of 0 to 600 seconds.

NOTE:

Currently, the value of Data Overflow Watch is predefined and cannot be changed. If

Inflow Control is No, Data Overflow Watch does not take effect and does not display anything.

Copy Pace: Pace (speed) for an initial copy activity for one volume. The default is Low.
• Low: Speed of initial copy activity is slower than Medium and High.

Advertising