140 Continuous Access XP Journal

Pair-Port Number Mismatch

Specified port in the remote disk

array is physically disconnected from

the local disk array.

Ensure that you specified the correct

remote disk array port. Correct the

port number if necessary.
Ensure that the local and remote disk

arrays are connected by cables to

each other. If the disk arrays are not

by cables, and retry the operation.
Ensure that the topology settings of

ports on the local and remote disk

arrays are correct.

Pair-Port Type Mismatch

Specified remote disk array port is

not configured as an RCU target

port.

Ensure that the remote disk array

port is configured as an RCU target

port.

Communication Failed

Local disk array is connected to the

remote disk array successfully, but a

logical communication timeout

occurred.

Ensure that the remote disk array

port and network relay devices (for

example, cables and switches) are

properly configured and functioning.

Logical Blockade

Failure occurred at a local disk array

port.

Repair the port status on the local

disk array.

Failure occurred at a remote disk

array port.

Repair the port status on the remote

disk array. After that, delete the path

using the Delete Path or Delete DKC

command, and add the path and

remote disk array again using the

Add Path or Add DKC command.

Failure occurred in the path relay

equipment.

Repair the path relay equipment.

After that, delete the path using the

Delete Path or Delete DKC

command, and add the path and

remote disk array again using the

Add Path or Add DKC command.

Connection cable is physically

broken.

Replace the broken cable. After that,

delete the path using the Delete Path

or Delete DKC command, and add

the path and remote disk array

again using the Add Path or Add

DKC command.

Program Error

Program error detected.

Delete the path using the Delete Path

or Delete DKC command, and add

the path and remote disk array

again using the Add Path or Add

DKC command.

<blank>

Path was not established.

Delete the failed path. You might

need to change the minimum paths

setting or delete the remote disk

array to delete the path. After

deletion finishes, add the path and

remote disk array using the Add Path

or Add DKC command.

Table 29

Troubleshooting problems with status of logical paths (continued)

Pair status

Description

Corrective action