Table 7 suspend types (psue), Continuous access xp journal suspension condition, 7 suspend types (psue) – HP StorageWorks XP Remote Web Console Software User Manual

Page 34: Table 7 on, Continuous, Access xp journal suspension condition” on, Table 7

Advertising
background image

34

Continuous Access XP Journal

Continuous Access XP Journal secondary data volumes (the consistency status is displayed only at the

secondary disk array).

Continuous Access XP Journal suspension condition

Continuous Access XP Journal operations involve additional suspension conditions related to asynchronous

journal operations. The primary and secondary disk arrays can detect Continuous Access XP Journal

suspension conditions and suspend Continuous Access XP Journal pairs. The primary disk array stores the

differential bitmap per Continuous Access XP Journal primary data volume in shared memory. The

secondary disk array stores the differential bitmap per Continuous Access XP Journal secondary data

volume in shared memory. When a Continuous Access XP Journal pair is suspended, the tracks containing

the following journal are marked in the differential bitmap as modified (to be copied during the pairresync

operation):

Journal data the primary disk array has created, but has not sent to the secondary disk array yet
After marking these primary data volume tracks as modified, the primary disk array discards the

journal data.

Journal data that has been sent to the secondary disk array, but the secondary disk array has not

acknowledged
After marking these primary data volume tracks as modified, the primary disk array discards the

journal data. This ensures that journal data lost during transmission to the secondary disk array is

identified and marked.

Journal data that has reached the secondary disk array, but has not been restored yet
After marking these primary data volume tracks as modified, the primary disk array discards the

journal data. Therefore, the secondary disk array can check and mark journal data that has not been

restored.
The primary disk array does not discard journal data from the master journal volume until the primary

disk array receives the restored journal volumes’ sequence numbers, which are included in read journal

commands from the secondary disk array.

Primary data volume records updated by host-requested write I/Os after the pair was suspended

Table 7

Suspend types (PSUE)

Type

Applies to

Description

PSUE, S-VOL Failure

Primary data volume,

Secondary data volume

The primary disk array detected an error during

secondary disk array communications or during

update copy. In this case, the secondary data volume

suspend type is usually PSUE-S-VOL Failure.

PSUE, MCU IMPL

Primary data volume,

Secondary data volume

The primary disk array could not find valid control

information in its nonvolatile memory during IMPL.

This condition occurs only if the primary disk array is

without power for more than 48 hours (for example, a

power failure and fully discharged backup batteries).

PSUE Initial Copy Failed

Primary data volume,

Secondary data volume

The Continuous Access XP Journal pair was

suspended before the initial copy operation was

complete. Data on the secondary data volume is not

identical to data on the primary data volume.

PSUE, MCU P/S OFF

Secondary data volume

The primary disk array is powered off.

Advertising