Figure 39 add dkc pane, 39 add dkc pane – HP StorageWorks XP Remote Web Console Software User Manual

Page 81

Advertising
background image

Continuous Access XP Journal user guide

81

• Remote disk array’s serial number.
• Remote disk array’s controller ID.

NOTE:

The controller ID for an XP10000/XP12000 disk array is 4.

• Path group ID. The path group ID is within the range of 1-FF (hexadecimal). Up to 64 path group

IDs can be registered per disk array.

NOTE:

In the current version, the path group IDs always take the default values and cannot be

changed.

8.

In the Add DKC pane, select a primary and remote disk array port to configure a logical path.

9.

Click Option.

10.

In the DKC Option pane, configure logical path and disk array options. For more information about the

options, see

Changing options for logical paths and disk arrays

” on page 82.

11.

Click Set to close the DKC Option pane.

12.

In the Preset list, check the settings you made.
• To modify a setting, select and right-click the setting from the Preset list, and select Modify. A pane

appears where you can modify the setting.

• To cancel a setting, select and right-click the setting in the Preset list, and select Cancel.

13.

Click Apply to apply the settings.

NOTE:

If an error occurs, the right-most column of the Preset list displays the error code. To view

detailed information about the error, right-click the error code, and select Error Detail. An error

message appears providing detailed information about the error.

Figure 39

Add DKC pane

The Add DKC pane displays the following:

DKC S/N: Enter the remote disk array’s five-digit serial number.

Controller ID: Enter the remote disk array’s controller ID (that is, disk array family ID).

Advertising