Table 16 illegal port combinations (for front cl1), 16 illegal port combinations (for front cl1), Table 16 – HP StorageWorks XP Remote Web Console Software User Manual

Page 41

Advertising
background image

Continuous Access XP Journal user guide

41

primary site. Also, if you configure a system in a three-data-center (3DC) cascading configuration (see

Combining Continuous Access XP Journal with Continuous Access XP (3DC cascading configuration)

” on

page 60) and you use the CL1-A port as an RCU target port in the Continuous Access XP Journal primary

site, you must not use the CL1-A or CL5-A port as an RCU target port in the Continuous Access XP

secondary site. As these examples indicate, you must avoid using illegal combinations of an RCU target

port in the Continuous Access XP Journal primary site and a target port in the Continuous Access XP

Journal primary site. Also, when configuring a system in a 3DC cascading configuration, you must avoid

using illegal combinations of an RCU target port in the Continuous Access XP Journal primary site and an

RCU target port in the Continuous Access XP secondary site.
If you use illegal port combinations, Continuous Access XP Journal remote copy operations are likely to be

suspended due to failures. If a Continuous Access XP Journal remote copy operation is suspended due to a

failure, the following problems occur and the remote copy operation cannot be performed:

The primary disk array cannot read data from the primary data volume.

In a system in a 3DC cascading configuration, the intermediate site cannot read data from a volume

used as both a Continuous Access XP Synchronous secondary volume and a Continuous Access XP

Journal primary data volume.

Table 16

Illegal port combinations (for FRONT CL1)

Location
(channel adapter

number)

Illegal port combinations

Location
(channel adapter

number)

Illegal port combinations

RCU target port

in Continuous

Access XP

Journal primary

site

Target port in

Continuous

Access XP

Journal primary

site, or RCU

target port in

Continuous

Access XP

secondary site

RCU target port

in Continuous

Access XP

Journal primary

site

Target port in

Continuous

Access XP

Journal primary

site, or RCU

target port in

Continuous

Access XP

secondary site

1E (Basic)

CAUTION:

If the

disk array is an

XP10000, the

location is 1A, not

1E.

CL1-A

CL1-A, CL5-A

1G (Add.2)

CL1-J

CL1-J, CL5-J

CL3-A

CL3-A, CL7-A

CL3-J

CL3-J, CL7-J

CL5-A

CL1-A, CL5-A

CL5-J

CL1-J, CL5-J

CL7-A

CL3-A, CL7-A

CL7-J

CL3-J, CL7-J

CL1-B

CL1-B, CL5-B

CL1-K

CL1-K, CL5-K

CL3-B

CL3-B, CL7-B

CL3-K

CL3-K, CL7-K

CL5-B

CL1-B, CL5-B

CL5-K

CL1-K, CL5-K

CL7-B

CL3-B, CL7-B

CL7-K

CL3-K, CL7-K

CL1-C

CL1-C, CL5-C

CL1-L

CL1-L, CL5-L

CL3-C

CL3-C, CL7-C

CL3-L

CL3-L, CL7-L

CL5-C

CL-1C, CL5-C

CL5-L

CL1-L, CL5-L

CL7-C

CL3-C, CL7-C

CL7-L

CL3-L, CL7-L

CL1-D

CL1-D, CL5-D

CL1-M

CL1-M, CL5-M

CL3-D

CL3-D, CL7-D

CL3-M

CL3-M, CL7-M

Advertising