Table 29 – HP StorageWorks XP Remote Web Console Software User Manual

Page 138

Advertising
background image

138 Continuous Access XP Journal

A Continuous Access XP Journal error

message is displayed on the Command

View XP management station.

Remove the error cause, and retry the Continuous Access XP Journal

operation.

The status of a logical path is not

normal.

Check the path status in the DKC Status pane, and see

Table 29

.

The pair status is

suspended

.

Check the pair status in the Pairdisplay pane, and see

Table 30

.

Paircreate or pairresync operation

resulted in a timeout error.

If the timeout error was caused by a hardware failure, a SIM is

generated. If this occurs, call the HP Support Center, and retry

Continuous Access XP Journal operations after the problem is solved.
If no SIM was generated, wait for 5 or 6 minutes, and check the pair

status of the pairs being created or resumed. If the pair status changed

correctly, the failed operation completed after the timeout message was

issued. If the pair status did not change as expected, heavy workload

might have prevented the Continuous Access XP Journal operation from

being completed. In this case, retry the Continuous Access XP Journal

operation when the disk array has a lighter workload.

There is a pinned track on a Continuous

Access XP Journal volume.

See ”

Pinned track recovery for Continuous Access XP Journal volumes

on page 145 for instructions.

Table 29

Troubleshooting problems with status of logical paths

Pair status

Description

Corrective action

Initialization Failed

Link initialization procedure for the

remote disk array failed.

Ensure that the local and remote disk

arrays are connected correctly via

cables.
Ensure that you entered the correct

serial number (S/N) of the remote

disk array and the correct path

parameters (for example, local disk

array port, remote disk array port,

and controller ID).
Ensure that the topology settings of

the local and remote disk array ports

are correct.

Communication Time Out

Communication between the local

and remote disk arrays timed out.

Ensure that the remote disk array is

powered on, and NVS and cache

are fully functional.
Ensure that the network relay devices

(cables, connectors, switches,

ESCDs, extender devices,

communication lines, and all other

devices connected to the extenders)

are properly configured and

functional.
Delete the failed path. You might

need to change the minimum paths

setting or delete the remote disk

array to delete the path. After

deletion finishes, add the path or

remote disk array.

Table 28

General troubleshooting information for Continuous Access XP Journal (continued)

Error

Corrective action

Advertising