Figure 57 pairresync pane, 57 pairresync pane – HP StorageWorks XP Remote Web Console Software User Manual

Page 121

Advertising
background image

Continuous Access XP Journal user guide 121

3.

If any pair was suspended due to an error condition (use the Pairdisplay pane to view the suspend

type), ensure that the error condition has been removed. The primary disk array will not resume the

pairs until the error condition has been removed.

4.

In the tree, select Subsystem or a port.

5.

In the list, select and right-click the pair you want to restore. The pair status must be PSUS or PSUE.

6.

Select Pairresync. The Pairresync pane appears.

7.

In the Pairresync pane, select the desired options for the pairs.

8.

Click Set to close the Pairresync pane.

9.

In the Preset list in the Pair Operation pane, check the settings you made.
• To modify a setting, select and right-click the setting, and select Modify.
• To cancel a setting, select and right-click the setting, and select Cancel.

10.

Click Apply to restore pairs.

NOTE:

If an error occurs, the right-most column of the Preset list displays the error code. To view

detailed information about the error, right-click the error code, and select Error Detail. An error

message appears providing detailed information about the error.

11.

In the list of the Pair Operations pane, verify that the pairs were restored successfully. If the pair was

restored, the status of the pair is COPY or PAIR.
To monitor the progress of restoring pairs, click Refresh to update the information in the list or use the

Pairdisplay pane (see ”

Displaying detailed information about journal groups

” on page 96) to monitor

the detailed status of each pair.

Figure 57

Pairresync pane

The Pairresync pane displays the following:

Range: Specify the restore range. If you select two or more pairs in the same consistency group, the

default is LU. Otherwise, the default is Group.
• LU: Only the specified pairs are restored.
• Group: All pairs in the same consistency groups as the selected pairs are restored.

NOTE:

If the following two conditions are satisfied and you click Apply, a warning message is

displayed and processing cannot continue:
• The Preset list contains two or more pairs belonging to the same consistency group.
• The Range column displays Group for at least one of the above pairs.
To continue processing, do one of the following:
• Ensure that the Range column displays LU for all pairs in the same consistency group.
• In the Preset list, select all but one pair in the same consistency group, right click the selected

pairs, and select Delete.

Priority: Specify the desired priority (1-256) (scheduling order) for the pair-restoring operations.