142 Continuous Access XP Journal

Table 31

provides troubleshooting instructions for Continuous Access XP Journal pair suspension.

Hardware failures affecting cache memory and shared memory of the primary or secondary disk array

might also cause Continuous Access XP Journal pairs to be suspended.

Continuous Access XP Journal error codes

The Command View XP management station or XP Remote Web Console displays an error message when

an error occurs during Continuous Access XP Journal operations. The error message describes the error

and displays an error code consisting of four digits. The error message might also include a local disk

array SVP error code. If you need to call the HP Support Center for assistance, report the error codes.

Table 31

Resolving Continuous Access XP Journal pair suspension

Classification

Causes of suspension

SIM

Recovery procedure

Primary disk array

hardware or

secondary disk

array hardware

Hardware redundancy was lost due to

some blockade condition. As a result,

one of the following could not

complete: primary-secondary disk

array communication, journal creation,

copy operation, restore operation,

staging process, or de-staging process.
Journals cannot be retained because

some portion of cache memory or

shared memory was blocked due to

hardware failure.
Primary disk array failed to create and

transfer journals due to unrecoverable

hardware failure.
Secondary disk array failed to receive

and restore journals due to

unrecoverable hardware failure.
Drive parity group was in

correction-access status while the

Continuous Access XP Journal was in

COPY status.

DC0x
DC1x
DC2x

According to SIM, remove the

hardware blockade or failure.
Restore the failed volume pairs

(pairresync).

Communication

between the

primary and

secondary disk

arrays

Communication between disk arrays

failed because the secondary disk

array or network relay devices were not

running.
Journal volumes remained full even

after the timeout period elapsed.

DC0x
DC1x

Remove the failure from the primary

and secondary disk arrays or network

relay devices.
If necessary, increase resources as

needed (for example, amount of cache,

number of paths between primary and

secondary disk arrays, and parity

groups for journal volumes).
Restore the failed pairs (pairresync).

RIO overload or

RIO failure

Unrecoverable RIO (remote I/O)

timeout occurred because the disk

array or networks relay devices were

overloaded.
RIO could not be finished due to a

failure in the disk array.

DC2x

Delete failed pairs (pairsplit-S).
If necessary, increase resources as

needed (for example, amount of cache,

number of paths between primary and

secondary disk arrays, and parity

groups for journal volumes).
Re-establish failed pairs (paircreate).

Planned power

outage to the

primary disk array

Continuous Access XP Journal pairs

were temporarily suspended due to a

planned power outage to the primary

disk array.

DC8x

None. Primary disk array automatically

removes the suspension condition when

the disk array is powered on.