HP HSG Array Controller User Manual

Page 154

Advertising
background image

B-14 StorageWorks Fibre Channel Storage Switch User's Guide

Compaq Confidential – Need to Know Required

Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:

Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM

To load the Compaq StorageWorks Fibre Channel Firmware from an
ALPHA NT machine:

1.

Copy the files Rshd.exe and Cat.exe from
D:\DSGGA\Firmware\NTAlpha\Rshd.exe,
D:\DSGGA\Firmware\NTAlpha\Cat.exe, and the firmware file
D:\DSGGA\firmware\NTAlpha\V1.6b onto the top root directory C:\.

Where D:\ is the drive letter for the CD and C:\ is the root directoryfor your
system.

2.

Double-click on Rshd.exe. Rshd will just run in the background. Leave
Rsh running. RSH is a small server program that allows the Switch to
request the firmware from the host over the Ethernet.

3.

Run Telnet to connect to the Switch and login as:

admin

password:

password

4.

Then type:

flashDownload "192.168.60.200",

"administrator","V1.6b"

The 192.168.60.200 above must be replaced with the IP address of your Alpha
host computer. You may have to change the V1.6b to what ever the current
Firmware file is called. If you are logged into an NT system under an account
other than administrator you will have to modify "administrator" to the
account you are using to run Rshd.exe which must also be run from the
directory that contains cat. An example of the output follows:

1330320+203572+427356

writing flash 0 .............................

writing flash 1 .............................

download complete

value = 0 = 0x0

switch:admin>

5.

Click on the RSHD window and type Control C or select File and Exit

6.

to stop Rshd from running.

7.

Select the Telnet window and type reboot to cause the Switch to reboot
and copy the flash into the ram and come up running the latest Compaq
StorageWorks Switch Firmware.

Advertising