Reboot, Syslogdip, Switchdisable – HP HSG Array Controller User Manual

Page 193

Advertising
background image

Telnet Commands B-53

Compaq Confidential – Need to Know Required

Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:

Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM

reboot

Figure B-31 shows the

reboot

command which reboots the Switch to the

stored configuration in flash memory and takes about 1 1/2 minutes. The
Switch maybe in any operational state (enabled or disabled) before rebooting.

admin> reboot

Figure B-31. reboot Command Example

syslogdIp

Figure B-32 show the

syslogdIp

command which sets or displays the

Switches system log daemon IP address.

The command syntax is

syslogdIp <“ip address”>.

admin> syslogdIp

syslog daemon’s address: 0.0.0.0

value = 35 = 0x23 = ’#’

Figure B-32. syslogdIp Command Example

switchDisable

Figure B-33 shows the

switchDisable

command used for diagnostic tests,

similar maintenance functions, or replacing a faulty Switch.

You can observe and verify this process by watching the front panel LEDs
change color from green to slow flashing amber as each port goes inactive.

admin> switchDisable

value = 0 = 0x0

Figure B-33. switchDisable Command Example

Advertising