flashShow

Figure B-11 shows the flashShow command which displays the Switch’s
configuration status. The display shows remote host and flash configuration
information for flash-0 and flash-1 (a mirrored image of flash-0 and included
as a fail safe device).

admin> flashShow

Ethernet address: 0:60:69:0:4:64

Nvram data: ei(0,0)host:/usr/switch/firmware
e=192.168.64.146:ffffff00 g=192.168

.64.1 u=user tn=open146

Config fl-0 fl-1

------ ---- ----

version 0002 0002

flags 0000 0000

domain 0001 0001

syslogd_ip 0.0.0.0 0.0.0.0

fc_ip_addr 0.0.0.0 0.0.0.0

fc_ip_mask 0.0.0.0 0.0.0.0

bb_credit 0010 0010

df_size 0840 0840

r_a_tov 2710 2710

e_d_tov 07d0 07d0

op_mode 0000 0000

vc_link_ctl 0000 0000

vc_class2 0002 0002

vc_class3 0003 0003

vc_multicast 0007 0007

vc_priorities 0,1,2,2,2,2,3,3
0,1,2,2,2,2,3,3

vc_pid_map 767625432 767625432

frm collection piling piling

alt bb_credit 0000 0000

open bb_credit 0004 0004

send FAN frames yes yes

ql_ports n/c n/c

ql_peer n/c n/c

csum 4cc2 OK 4cc2 OK

Figure B-11. flashShow Command Example