5-18 StorageWorks Fibre Channel Storage Switch User's Guide

Compaq Confidential – Need to Know Required

Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:

Part Number: AA-RHBYA-TE 135267-001 File Name: f-ch5 Managing the Switch over the Web Last Saved On: 4/7/99 12:36 PM

Table 5-4

Port Detail View Page Fields

Field

Description

Port Number

The port number.

Port Status

The port state follows the GBIC type. The possible port states include:

No_Card no card present in this Switch slot

No_Module no GBIC module in this port

No_Light the module is not receiving light

No_Sync the module is receiving light but is out of sync

In_Sync the module is receiving light and is in sync

Laser_Flt the module is signaling a laser fault (defective GBIC)

Port_Flt the port has been marked faulty (defective GBIC, cable, or
device)

Diag_Flt the port failed diagnostics (defective G_Port or FL_Port card
or motherboard)

Online the port is up and running

Lock_Ref the port locking to the reference signal

Port Type

The port type (E_Port, G_Port or FL_Port).

Port Module (or GBIC
Module)

The GBIC type follows the port number. The four GBIC types include:

no GBIC present

sw shortwave GBIC

lw longwave GBIC

cu copper GBIC

Port World Wide Name

The World Wide Name for this port.

Interrupts

Total number of interrupts.

Unknown

Number of unknown interrupts.

Lli

Number of low level interface (LLI) interrupts.

Proc_rqrd

Number of interrupts with processing (CPU) required.

Timed_out

Number of timed out interrupts.