Table B-6
flashShow Command Field Descriptions

continued

Field

Description

df_size

The receive data field size.

r_a_tov

The resource allocation time out value.

e_d_tov

The error detect time out value.

op_mode

Operating mode.

vc_link_ctl

Virtual channel link control.

vc_class2

Virtual channel class 2.

vc_class3

Virtual channel class 3.

vc_multicast

Virtual channel multicast.

vc_priorities

The numbers displayed show the priorities assigned to each of
the Switch’s virtual channels. Positions 1 and 2, starting at the
left of the display, are fixed and displays 0 or 1.

The first position a 0 shows and indicates that this virtual
channel, assigned to handle internal Switch traffic, has the
highest priority. This priority value cannot be changed.

The second position, indicated with a 1, shows the priority
assigned by the virtual channel link control.

The third through eighth positions they can have only a 2 or a 3
indicating that the channel gives priority to either Class 2 frame
traffic or to Class 3 frame traffic.

vc_pid_map

Virtual channel Port ID time out map.

frm collection

Supports 2 frame collection methods

, piling and bundling.

alt bb_credit

This is the value used in an NL_Port's FLOGI.

continued