Diagshow – HP HSG Array Controller User Manual

Page 213

Advertising
background image

Telnet Commands B-73

Compaq Confidential – Need to Know Required

Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:

Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM

diagShow

Figure B-52 shows the

diagShow

command which summarizes the

diagnostics results run since the Switch was last booted, including POST
results. The fields are described in Table B-15.

NOTE: This command shows an FL_Port as being offline if you are running cross port
connected testing, the reason is that you can have only one Principle per Switch. The
FL_Port to FL_Port testing still proceeds even though this is NOT the correct way to
connect FL_Ports.

The command also allows you to loop on the command. For example,
diagShow 4 executes diagShow every 4 seconds continuously unless stopped
by pressing Return. This may be used to isolate a bad GBIC. A port with a
changing LLI_errs value is prefixed by "**" in the display. The example
below shows 2 passes, the first pass without an error on the line st11 (in bold)
and the second pass shows an error on the line st11 (in bold). The screen
shows:

Each port number diagnostic status (OK/BAD) and port state (up
(online)/down (offline))

Frames transmitted (frTx) frames received (frRx) and Low Level
Interface error count (LLI_errs) for active ports

Central memory status (OK/FAULTY)

Total diagnostics frames transmitted (Tx) and received (Rx) since boot,
which are normally the same, but may differ because of failure modes.

NOTE: Port 16 is the embedded port.

Advertising