B-78 StorageWorks Fibre Channel Storage Switch User's Guide

Compaq Confidential – Need to Know Required

Writer: Bill Reitz Project: StorageWorks Fibre Channel Storage Switch User's Guide Comments:

Part Number: AA-RHBYA-TE 135267-001 File Name: i-appb Telnet Commands Last Saved On: 4/7/99 12:36 PM

fspfShow

Figure B-54 shows the

fspfShow

command which displays Fibre Channel

Shortest Path First (FSPF) information. The fields are described in Table B-17.

admin> fspfShow

version = 2

domainID = 1

isl_ports = 0x00000000

minLSInterval = 5

fspfQ = 0x103ab560

fabP = 0x103abde0

agingTID = 0x103a98c0

agingTo = 10000

flushTID = 0x0

ddb_sem = 0x103ab530

fabP:

event_sch = 0x3

lsrRefreshCnt = 0

value = 20 = 0x14

Figure B-53. fspfShow Command Example

Table B-17

fspfShow Command Field Descriptions

Field

Description

version

The version of the FSPF protocol.

domainID

The local Switch’s domain ID.

isl_ports

A bitmap field that shows all local Switch
E_Ports.

other

The other fields represent internal FSPF
variables.